Part Number Hot Search : 
CSC04A M6221 Z02W10 IR2383 A1070 DL6SNE RT314110 MBT440
Product Description
Full Text Search
 

To Download LK4301-7R Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 K Series with PFC
150 Watt AC-DC Converters
Input voltage range from 85...255 V AC 1or 2 isolated outputs up to 48 V DC 4 kV AC I/O electric strength test voltage
LGA
* Rugged electrical and mechanical design * Integrated power factor correction * Operating ambient temperature range -40...71C with convection cooling
Selection chart
Output 1 Output 2 Input voltage
Uo nom
[V DC] 5.1 12 15 24 24 30 48 12 15 24
Io nom
[A] 25 12 10 6 6 5 3 6 5 3
Uo nom
[V DC] 12 15 24
Io nom
[A] 6 5 3
Ui
[V AC] 85...255 85...255 85...255 85...255 85...255 85...255 85...255 85...255 85...255 85...255
Efficiency hmin [%] 78 85 85 86 83 83 84 83 83 84
Type
Options
LK 4003-6R LK 4301-7R LK 4501-7R LK 4601-7R LK 5320-7R LK 5540-7R LK 5660-7R LK 5320-7R LK 5540-7R LK 5660-7R
-9, E, D, V, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1 -9, E, D, P, T, B1
www.power-one.com
Edition 4/04.2001
1
Cassette Style
Input
Input voltage AC Input frequency Power factor Inrush current limitation wide input range per IEC/EN 61000-3-2 by thermistor
K Series with PFC
85...255 V AC 50/60 Hz >95%
Output
Efficiency Output voltage setting accuracy Output voltage switching noise Line regulation Load regulation Minimum load Current limitation Operation in parallel Hold-up time
Ui nom, Io nom Ui nom, Io nom
IEC/EN 61204, total
Ui min...Ui max, Io nom Ui nom, 0.1...Io nom, symmetrical output load
not required rectangular U/I characteristic by current limitation Ui nom, Io nom
up to 86% 0.6% Uo nom typ. 100 mVpp typ. 0.1% typ. 0.4% 0A typ. 110...100% Io nom 20 ms
Control and protection
Input fuse Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature Output voltage adjustment Inhibit Status indication not user accessible 4 AT typ. 80% Ui min typ. 115% Ui max
varistor no-load, overload and short circuit proof suppressor diode in each output switch-off with auto restart TTL input, output(s) disabled if open circuit LEDs: OK, inhibit, overload
typ. 130% Uo nom TC typ. 100C 0...110% Uo nom
Safety
Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA 22.2 No. 950 class I IP 30 2 kV AC 4 kV AC 1 kV AC 0.1 kV AC
I/case I/O O/case O/O
EMC
Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Conducted disturbances Electromagnetic emissions IEC/EN 61000-4-2, level 4 (8/15 kV) IEC/EN 61000-4-3, level 3 (10 V/m) IEC/EN 61000-4-4, level 4 (2/4 kV) IEC/EN 61000-4-5, level 3 (2 kV) IEC/EN 61000-4-6, level 3 (10 V) CISPR 22/EN 55022 criterion A criterion A criterion A criterion A criterion A class B
www.power-one.com
Edition 4/04.2001
2
K Series with PFC
Environmental
Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump Random vibration MTBF
150 Watt AC-DC Converters
Ui nom, Io nom, convection cooled Ui nom, Io nom
non operational IEC/EN 60068-2-3, 93%, 40C IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-27, 6 ms IEC/EN 60068-2-29, 6 ms IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217F, GB, 40C -25...71C -25...95C -40...100C 56 days 0.35 mm/5 gn 100 gn 40 gn 4.9 gn rms 514'000 h
Options
Extended temperature range -40...71C, ambient, operating Electronic inrush current limitation Output voltage adjustment 40...100 % Uo nom, excludes feature R and vice versa Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D Current sharing Cooling plate -9 E P D0...D9 V0, V2, V3 T B1
Pin allocation
Pin 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 LK 4003 Vo1+ Output 1 Vo1- S+ S- R i D V T N P Output 1 Sense Sense Control of Uo1 Inhibit Save data ACFAIL Current sharing Protective earth Input Input LK 4301, LK 4501, LK 4601 Vo1+ Output 1 Vo1+ Vo1- Output 1 Vo1- S+ Sense S- Sense R Control of Uo1 i Inhibit D Save data T N N P P Current sharing Protective earth Input Input LK 5000 Vo2+ Output 2 Vo2+ Vo2- Output 2 Vo2- Vo1+ Output 1 Vo1- Output 1 R Control of Uo1 i Inhibit D Save data T N N P P Current sharing Protective earth Input or Neutral Input or Phase
S10010
10001
Connector type H15 30 26 22 18 14 10 6
32 28 24 20 16 12 8
4
30/32 Type H15 S2
4/6
www.power-one.com
Edition 4/04.2001
3
Cassette Style
Mechanical data
Tolerances 0.3 mm (0.012") unless otherwise indicated.
159 (6.25") 4.5 (0.18")
K Series with PFC
European Projection
7 TE
9 TE
111 (3U) (4.37")
89 (3.50")
Test jacks Option P (Uo) Option D (Uto) Option D (Uti) LED i LED OK LED IoL
Measuring point of case temperature TC
50 (1.97")
171.93 (6.77") (DIN 41494) 168.5 (6.63")
S09002
6.5 (0.26")
80 (3.15")
Accessories
Front panels 19" (Schroff/Intermas) Mating H15/H15S4 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting
www.power-one.com
Edition 4/04.2001
4


▲Up To Search▲   

 
Price & Availability of LK4301-7R

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X